Reference standard:IEC 60227-2、IEC 60245-2、UL62、UL2556
Main function:
1. Test sample type: two core single phase, three-phase three wire, three-phase four wire;
2. Test mode: no load, single-phase (two core), three-phase (three-phase three wire / three-phase four wire) can be selected;
3. Test result judgment method:
■ Indicator light indication: O, R, s, t phase disconnection and automatic shutdown;
■ Indicator light indication: R / s, R / T, S / T, R / O, S / O, t / O short circuit and automatic shutdown;
■ Indicator light indication: O, R, s, t are short circuited with pulley and stop automatically;
■ Qualified judgment: the tested wire has no open circuit or short circuit phenomenon until the preset number of times is automatically stopped
Main parameters:
1. Controller: 7-inch HMI;
2. Drive mode: Servo motor.
3. Test speed: 0.1~0.5m/s
4. Test distance: 1m;
5. Test current: AC0.01-35.00A;
6. Test voltage:
■ Single phase: AC0~250.0V adjustable;
■ Three-phase three: AC0~450.0V adjustable;
7. Weight: 0.5 kg, 1.0 kg, 2.0 kg, 3.0 kg, 7.0kg、14N, 21N, 28N
8. Pulley structure: φ60, 80, 120, 160, 200mm
9. Counter: LCD display, 0~9999999;
10. Dimensions: W1900mm × D700mm × H1500mm;