Reference standard: UL 1277、UL854、UL 13
Technical parameters:
1. Impact height: 20mm~1000mm arbitrary setting
2. Impact hammer: 1.36kg (3lb), 2.27kg (5lb), 4.54kg (10lb), 11.34kg (25lb), 22.7kg (50lb) 5 weights,
8 shapes of impact hammer, can be replaced at will.
3. Specification of impact anvil;
4. Specification of steel rod: Φ19mm
5. Working mode: The electromagnet is energized to hold the weight, and the power is turned off to release the weight
6. Equipment test power supply: three-phase 380V
7. There are4pcs 3W/120V neon lamps
8. The voltage output is controlled by a switch, and the switch on voltage is indicated.